Incandescent CFL Metal Halide Lumens Needed LED Equivalent Energy Savings
250 65 100 4,000 30-40 Watts 70%
300 80 125 4,800 40 Watts 70%
400 100 150 6,000 50-60 Watts 70%
450 125 175 7,000 60 Watts 70%
500 150 250 8,000 75-80 Watts 70%
600 175 320 10,000 100 Watts 70%
1000 300 400 16,000 120-150 Watts 70%
2000 500 750 30,000 240-300 Watts 70%
NA NA 1000 40,000 300 Watts 70%
NA NA 1500 60,000 450 Watts 70%
NA NA 2000 80,000 600 Watts 70%
The LED Conversion Table at Central Lighting Service is an invaluable resource designed to make your transition from traditional incandescent, HID, or fluorescent lamps to modern, energy-efficient LED lighting as smooth and straightforward as possible. Upgrading your lighting can be a complex process, but our easy-to-use table simplifies it by offering detailed comparisons of wattage and lumens, allowing you to select the perfect LED replacement that either matches or exceeds the brightness and performance of your current lighting setup. This tool is ideal for anyone looking to retrofit an entire building or simply upgrade a few fixtures, ensuring that you make well-informed decisions that optimize both energy savings and lighting quality.
The shift to LED lighting is not just about reducing energy consumption; it’s also about improving the overall ambiance and functionality of your space. Our LED Conversion Table helps you navigate this transition by providing you with all the information you need to make the best choice. With the right LED replacement, you can achieve significant energy savings, lower maintenance costs, and a longer lifespan for your lighting fixtures. Additionally, Central Lighting Service offers a Utility Rebate Map, enabling you to save even more on your investment. You can find additional information at DSIRE – Lighting Rebates

When considering a switch to LED lighting, it’s important to think about your specific lighting needs. For spaces requiring greater brightness, opting for LEDs with higher lumen output is a smart choice. However, it’s also crucial to ensure that there is enough room for proper fitment and cooling when replacing lamps, as these factors can impact the performance and longevity of your new LED Lamps / Retrofits.

Moreover, it’s worth noting that Metal Halide and High-Pressure Sodium (HPS) lamps often claim 2-3 times the lumens listed in their specifications. However, these traditional lighting sources degrade rapidly, with up to 70% of their brightness lost over their lifespan. In fact, approximately 30% of their lumens can diminish within the first 1,000 hours of use alone. This significant drop in light output over time underscores the importance of switching to more reliable, long-lasting LED lighting solutions.
By utilizing the LED Conversion Table at Central Lighting Service, you not only ensure that your lighting choices are well-informed but also that your space is illuminated with the highest quality, energy-efficient lighting available today.